Get an assessment
AFRC Lab › Services › Fire
Fire · Windows, doors & façades · Accredited partners

Prove the window — and the way it's installed — is fire-compliant.

A window can carry an energy rating and still have no fire answer. We assemble the fire evidence for your windows and doors and the seal around them — the system's fire behaviour, bushfire (BAL) where it applies, and the fire-rated perimeter — and prove it to the NCC through a fire-engineered Performance Solution, delivered with our accredited fire partners and coordinated by AFRC Lab.

NCC 2025 · Vol 1 Section C (C4, Spec 12) + FSVM · Vol 2 H3 · AS 5113 · AS 1530 series · AS 5637.1 (ISO 9705) · AS 3959 / AS 1530.8 · AS 1905.1

When the frame is combustible, the rating doesn't answer the fire question

In Class 2 apartments and other buildings with non-combustible external-wall requirements, a combustible window frame — uPVC, timber or some composites — and the seal around the opening need a fire case of their own. An energy rating speaks to U-value and SHGC; it says nothing about ignition, fire spread or how the assembly behaves in a fire. That gap is increasingly scrutinised, and it falls to the builder and certifier to close before the windows are procured — not after handover.

How a combustible frame is proven compliant

Where a prescriptive non-combustibility path doesn't fit, the window is justified through a fire-engineered Performance Solution. It rests on three questions, each supported by recognised test methods rather than assertion.

1 · Ignition

How readily it ignites

uPVC is self-extinguishing and resists ignition — positions supported by testing to AS 5113, AS 5637.1 (ISO 9705) and the AS 1530 series. A bushfire (BAL) rating strengthens the case where AS 3959 applies, and the external wall is otherwise non-combustible.

2 · Spread

Whether fire can travel

Framing sits in discrete locations around the openings — not vertically continuous across fire compartments — with a non-combustible wall build-up and barriers such as aprons, spandrels or cavity fire-stopping that contain any spread.

3 · Evacuation

Occupants & brigade

The framing is a minor part of the building's fire load — most of it is the apartment contents — and its location doesn't obstruct firefighting. For taller buildings it's read alongside the wider fire-safety measures and protected egress.

The window and the way it's installed — both have to hold

Fire compliance isn't only the window. The joint between the window and the wall is part of the building's fire-resisting line, so the perimeter seal has to be evidenced as much as the frame itself.

The system

Frame, glazing & bushfire

The fire behaviour of the frame and glazing, and bushfire (BAL) performance to AS 3959 / AS 1530.8 where the site demands it — evidenced through accredited testing and assessment.

The install

A fire-rated perimeter

The seal around the opening carries the fire separation. A fire-rated perimeter — for example an intumescent joint seal that expands under heat to maintain the separation — evidenced to the relevant fire-resistance test method, so the installed detail holds, not just the catalogue window.

Testing to Performance Solution to certificate

Fire compliance for glazed facades, windows and doors spans testing, engineering and certification. We coordinate it end to end with accredited fire partners — AFRC Lab is the single point of contact, the specialists deliver the accredited work.

Test

System fire testing

Facade and fenestration fire testing to the relevant AS 1530 / AS 5113 / AS 1905.1 methods through accredited partners.

Engineer

Performance Solutions

Fire-engineered Performance Solutions and the Fire Safety Verification Method where a prescriptive path doesn’t fit.

Certify

One point of contact

From project to certificate, coordinated by AFRC Lab and delivered with our accredited fire partners.

Independent & product-neutral. AFRC Lab is a third party. We map the method, specify the performance it must meet, train your people and verify the outcome — we don't supply, sell or endorse any product or brand. You procure systems and materials from your own suppliers; our role is to make the result defensible, whoever you buy from. Generic guidance is a starting point only; every Performance Solution is project-specific, and final NCC compliance is determined by the appointed fire engineer and certifier.

Three steps — and the first one's easy

You don't commit to a full engagement to find out where you stand. We start with a quick look and only go further if it's worth it. And to keep it in proportion: on a multi-storey project, proving the fire case usually costs about what a couple of windows do — small against the package it clears.

Step 1

Quick desktop review

We take a first look at the window and the building and give you a simple yes/no — is it likely to achieve compliance, and is it worth proceeding? Fast and low-cost.

Step 2

Letter to the fire authority

If it's a yes, we draft the fire-engineered Performance-Solution submission — the letter to the fire engineer, certifier or authority.

Step 3

Verification letter

On approval, you get a verification letter confirming the window's fire compliance for the project.

Bring us the fire question.

Tell us the window, the building class and the requirement, and we’ll start with a quick desktop review — a simple yes/no before you commit to anything.

Get an assessmentDownload the uPVC & Class 2 brochure (PDF)