NCC climate zone 5 · Sydney · north facing · 10 years, 2015 to 2024
Thermally broken aluminium window with vapour-open tape, 20 mm hanno band bg1 pre-compressed foam tape
The detail
| Window | Generic thermally broken aluminium window, in-line reveal |
|---|---|
| Glazing | Double glazed IGU: clear float, argon, single-silver low-e on surface #3, warm-edge spacer |
| Flashing tape | Vapour-open flashing tape, min. 60 mm wide, lapped onto the wall wrap; sealed to the window frame as per the window manufacturer's details |
| Sill gap fill | Hanno Band BG1 pre-compressed foam tape, 20 mm (standard size), remainder air |
| Wall | Timber frame (KD treated pine), glass wool batts, plasterboard lining, vapour-permeable wall wrap, fibre-cement cladding |
| Climate | CZ5 Sydney (Warm temperate), north facing |
| Weather | 10 consecutive years, 2015 to 2024 |
Through the year

The section at its worst moment: temperature on the left; humid areas (green), condensation (blue) and the mould index on every surface on the right. The report includes the day-by-day animation of the last simulated year.
Nearest option that stays below the limit
Change the window: uPVC window with vapour-open tape, 20 mm hanno band bg1 pre-compressed foam tape, same climate zone and orientation. Peak mould index 1.03.
Free simulation report
This detail for your project: results for the window, the gap and the wall, the inputs and assumptions, the day-by-day animation, the 1:1 layered CAD detail and a verify page. Modelled evidence for a generic detail, to support an informed decision. Not a certification or a project verification.
Need it verified for your permit?
We model your own window, gap and wall section, with your materials and your site, in a 10-year MI6 Annual run: a project-specific assessment you can submit as evidence.
Same detail in other climate zones (north facing)
- CZ1 Darwin below
- CZ2 Brisbane exceeds
- CZ3 Alice Springs below
- CZ4 Mildura exceeds
- CZ6 Melbourne exceeds
- CZ7 Canberra exceeds
- CZ8 Thredbo exceeds
Indicative simulation result for a generic detail, to support an informed decision: not a certification or a project verification. Materials are typical generic products with standard properties, except the Hanno Band BG1 pre-compressed foam tape (where shown), which is modelled on the manufacturer's data. Mould index is the published measure. The hygrothermal engine is verified against the HAMSTAD and EN 15026 benchmarks: read the verification report.