AFRC Lab Window-to-wall explorer

NCC climate zone 7 · Canberra · north facing · 10 years, 2015 to 2024

Thermally broken aluminium window with vapour-open tape, 20 mm hanno band bg1 pre-compressed foam tape

Exceeds the mould limitwhole detail, AIRAH DA07 mould index, NCC F8V1 / H4V5 limit of 3
Window
5.28peak mould index, limit 3
Exceeds the mould limit
Gap
0.81peak mould index, limit 3
Stays below the mould limit
Wall
0.77peak mould index, limit 3
Stays below the mould limit

The detail

WindowGeneric thermally broken aluminium window, in-line reveal
GlazingDouble glazed IGU: clear float, argon, single-silver low-e on surface #3, warm-edge spacer
Flashing tapeVapour-open flashing tape, min. 60 mm wide, lapped onto the wall wrap; sealed to the window frame as per the window manufacturer's details
Sill gap fillHanno Band BG1 pre-compressed foam tape, 20 mm (standard size), remainder air
WallTimber frame (KD treated pine), glass wool batts, plasterboard lining, vapour-permeable wall wrap, fibre-cement cladding
ClimateCZ7 Canberra (Cool temperate), north facing
Weather10 consecutive years, 2015 to 2024

Animation

10-year animation of temperature, humidity and mould growth in this junctionPlays here once the video library is published.

Nearest option that stays below the limit

Change the window: uPVC window with vapour-open tape, 20 mm hanno band bg1 pre-compressed foam tape, same climate zone and orientation. Peak mould index 0.82.

Detail report for your project

Project name and address, results for window, gap and wall, the 1:1 layered CAD detail and a verify page. Uses one report credit from your BTW plan (credits are shared with BTW). Valid for 12 months for the named project.

1 crediton your BTW plan, or $200 + GST one-off

Not your detail?

We model your own window, gap and wall section for your project with a 10-year MI6 Annual run.

$200+ GST per section, per projectAsk about custom modelling

Same detail in other climate zones (north facing)

Indicative design guidance for a generic detail, not a compliance certificate or a project verification. Materials are typical generic products with standard properties, except the Hanno Band BG1 pre-compressed foam tape (where shown), which is modelled on the manufacturer's data. Mould index is the published measure. The hygrothermal engine is verified against the HAMSTAD and EN 15026 benchmarks: read the verification report.