AFRC Lab Window-to-wall explorer

NCC climate zone 5 · Sydney · north facing · 10 years, 2015 to 2024

Aluminium window, no thermal break with vapour-open tape, full-depth hanno band bg1 pre-compressed foam tape

Exceeds the mould limitwhole detail, AIRAH DA07 mould index, NCC F8V1 / H4V5 limit of 3
Window
5.28peak mould index, limit 3
Exceeds the mould limit
Gap
0.12peak mould index, limit 3
Stays below the mould limit
Wall
1.06peak mould index, limit 3
Stays below the mould limit

The detail

WindowGeneric aluminium window (no thermal break), in-line reveal
GlazingDouble glazed IGU: clear float, argon, single-silver low-e on surface #3, warm-edge spacer
Flashing tapeVapour-open flashing tape, min. 60 mm wide, lapped onto the wall wrap; sealed to the window frame as per the window manufacturer's details
Sill gap fillHanno Band BG1 pre-compressed foam tape, custom cut to full depth
WallTimber frame (KD treated pine), glass wool batts, plasterboard lining, vapour-permeable wall wrap, fibre-cement cladding
ClimateCZ5 Sydney (Warm temperate), north facing
Weather10 consecutive years, 2015 to 2024

Through the year

The section at its worst moment: temperature, humidity, condensation and mould index

The section at its worst moment: temperature on the left; humid areas (green), condensation (blue) and the mould index on every surface on the right. The report includes the day-by-day animation of the last simulated year.

Nearest option that stays below the limit

Change the window: uPVC window with vapour-open tape, full-depth hanno band bg1 pre-compressed foam tape, same climate zone and orientation. Peak mould index 1.05.

Free simulation report

This detail for your project: results for the window, the gap and the wall, the inputs and assumptions, the day-by-day animation, the 1:1 layered CAD detail and a verify page. Modelled evidence for a generic detail, to support an informed decision. Not a certification or a project verification.

Freewith your name, company and project

Need it verified for your permit?

We model your own window, gap and wall section, with your materials and your site, in a 10-year MI6 Annual run: a project-specific assessment you can submit as evidence.

$200+ GST per section, per projectAsk for a project assessment

Same detail in other climate zones (north facing)

Indicative simulation result for a generic detail, to support an informed decision: not a certification or a project verification. Materials are typical generic products with standard properties, except the Hanno Band BG1 pre-compressed foam tape (where shown), which is modelled on the manufacturer's data. Mould index is the published measure. The hygrothermal engine is verified against the HAMSTAD and EN 15026 benchmarks: read the verification report.